    、各廠商服務器對應的陣列卡工具名稱以及粗略使用方法

    Megacli64/storcli64

    LSI MegaRAID SAS 2208/LSI MegaRAID SAS-3 3108/LSI MegaRAID SAS-3 3508

    > 服務器型號

    > HUAWEI 2288H V2

    > HUAWEI 2485 V2

    > HUAWEI 5885 V3

    > DELL R730xd

    > Lenovo x3750 M4

    > FiberHome R2200 V5

    > ZTE 8500 G3,ZTE 5300 G3,ZTE 5300 G4

    > IBM x3755 M3,IBM x3650 M3

    > H3C R6700 G3

    > HUAWEI 2288H V3

    > HUAWEI G560

    > NF5280 M5

    > NF8460 M5

    > HUAWEI 2488H V5

    > HUAWEI 2288 V5

    > 5288 V5

    > taishan系列

    HP專用hpssacli

    > 服務器型號

    > Hewlett-Packard Company Smart Array Gen系列 Controllers(rev 01)

    Adaptec SAS/PCIe 3/4 系列陣列卡工具均為arrconf(最新版)

    > 機型:

    > H3C R4900 G3

    > ZTE 5300 G4,ZTE 5500 G4

    > NF5280 M4

    LSI SAS 3008 陣列卡工具均為sas3ircu

    > 機型:

    > FiberHome R1200 V5

    > FiberHome R2200 V5

    > Sugon I620-G30

    > HUAWEI RH2288 V3

    名詞解釋

    > Controller:

    > IR:

    > Volume: 卷,基于物理驅動器通過創建冗余磁盤陣列所生成的虛擬磁盤。概念上等同于RAID冗余磁盤陣列。

    > Enclosure: 硬盤盒編號。

    > Bay: 即slot,指代硬盤盒的某個插槽。

    > HDD: Hard Disk Drive的縮寫,即普通機械硬盤。

    > SSD: Solid State Drive的縮寫,即固態硬盤。

    > SAS: 序列式SCSI(SAS:Serial Attached SCSI)是一種電腦集線的技術,其功能主要是作為周邊零件的數據傳輸,例如:硬盤、CD-ROM等設備而設計的界面。

    > SATA: 串行ATA(Serial ATA: Serial Advanced Technology Attachment)是一種電腦總線,負責主板和大容量存儲設備(如硬盤及光盤驅動器)之間的數據傳輸,主要用于個人電腦。

    二、陣列卡工具使用命令

    命令 Megacli64

    查詢

    # 查看陣列卡信息
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL
    # 查看所有陣列卡的所有陣列邏輯卷的所有信息
    /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
    # 查看物理磁盤信息
    /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL|egrep "Slot Number|PD Type|Raw Size|Firmware state|Media Type"|sed 's/Slot/\nSlot/g'
    /opt/MegaRAID/MegaCli/MegaCli64 -pdlist -aall | egrep 'Enclosure Device ID|Slot Number|Firmware state|Raw' | sed 's/En/\n------\nEn/g'
    # Adapter#0 -----raid卡控制器編號
    # Enclosure Device ID: 64 -----外殼設備ID,也就是raid卡的ID號
    # Slot Number: 6 ------磁盤槽位號
    # PD Type: SAS ------磁盤類型
    # Raw Size: 3.638 TB [0x1d1c0beb0 Sectors] -----大小
    # Firmware state: Online, Spun Up ------磁盤狀態
    # 查看RAID組信息
    /opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL|egrep "RAID Level|^Size|Slot Number|Virtual Drive"|sed 's/Virtual/\nVirtual/g'
    /opt/MegaRAID/MegaCli/MegaCli64 -ldinfo -lall -aall | egrep 'RAID Level|State|Number Of Drives|Size' |sed 's/RA/\n-------------\nRA/'
    # 查看RAID級別和對應的物理盤
    /opt/MegaRAID/MegaCli/MegaCli64 -ldpdinfo -aall | egrep 'Virtual Drive|RAID Level|PD:|Enclosure Device ID|Slot Number|Firmware state|Raw' | sed 's/Virtual/\n--------\nVirtual/;s/PD:/\n===========\nPD:/'
    /opt/MegaRAID/MegaCli/MegaCli64 -ldpdinfo -aall | egrep 'Virtual Drive|RAID Level|PD:|Enclosure Device ID|Slot Number|Firmware state|Raw' | sed 's/Virtual/\n--------\nVirtual/;s/PD:/\n===========\nPD:/' | grep 'Virtual\|Slot\|Firmware'
    # 查看物理磁盤個數
    /opt/MegaRAID/MegaCli/MegaCli64 -PDGetNum -aALL
    # 查看磁盤溫度
    /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL | egrep "Drive Temperature" | awk -F ":" '{print $2}'
    # 查看磁盤錯誤
    /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL|grep Error
    # Medai Error Count 表示磁盤可能錯誤,可能是磁盤有壞道,
    # 這個值不為0值得注意,數值越大,危險系數越高
    # Other Error Count 表示磁盤可能存在松動,可能需要重新再插入
    # 查看raid陳列中掉線的硬盤:
    /opt/MegaRAID/MegaCli/MegaCli64 -pdgetmissing -a0
    # 查看,開啟或關閉jbod模式(硬盤直通功能)
    查看:MegaCli -AdpGetProp -enablejbod -aALL
    打開:MegaCli -AdpSetProp -EnableJBOD -1 -aALL
    關閉:MegaCli -AdpSetProp -EnableJBOD -0 -aALL
    # 查看第1張陣列卡上一共有多少個raid陣列組(默認從0開始計數)
    /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -a0 | grep -i "Virtual Disk"
    # 陣列創建完后,會有一個初始化同步塊的過程,可以看看其進度
    /opt/MegaRAID/MegaCli/MegaCli64 -LDInit -ShowProg -LALL -aALL
    # 同上,但是以動態可視化文字界面顯示進度信息
    /opt/MegaRAID/MegaCli/MegaCli64 -LDInit -ProgDsply -LALL -aALL?
    # 查看陣列后臺初始化進度
    /opt/MegaRAID/MegaCli/MegaCli64 -LDBI -ShowProg -LALL -aALL
    # 同上,以動態可視化文字界面顯示?
    /opt/MegaRAID/MegaCli/MegaCli64 -LDBI -ProgDsply -LALL -aALL
    # 查看同步進度
    /opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -showprog -physdrv[252:3] -a0
    # 以動態可視化界面查看物理磁盤重建進度?
    /opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ProgDsply -PhysDrv [32:2] -a0
    # 查看raid卡日志,注意日志的輸出量可能較大,陣列卡對應的組建陣列等操作的詳細信息都可以在日志中查看?
    /opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL
    # 顯示Raid卡型號,Raid設置,Disk相關信息?
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL
    # 顯示適配器個數,只能查看機器上一共有多少張陣列卡,不能查看詳細信息?
    /opt/MegaRAID/MegaCli/MegaCli64 -adpCount
    # 顯示適配器時間?
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpGetTime –aALL
    # 查看BBU的詳細信息?
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll
    # 查看BBU電池的充電狀態?
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus - aALL |grep 'Charger Status'
    # 顯示BBU狀態信息?
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL
    # 顯示BBU容量信息?
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuCapacityInfo -aALL
    # 顯示BBU設計參數?
    /opt/MegaRAID/MegaCli/ MegaCli64 -AdpBbuCmd -GetBbuDesignInfo -aALL
    # 顯示當前BBU屬性?
    /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -aALL

    外來配置

    # 掃描外來配置的個數:
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -scan -a0
    # 查看當前的磁盤在normal時的位置
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -preview -a0
    # 來導入配置,恢復虛擬磁盤組
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -import -a0
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -dsply -a0
    # 刪除外來配置
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -clear -a0
    # ** 此命令慎用 **
    # 這里的a0表示第一個raid卡控制器上的外來配置
    MegaCli64 -cfgforeign -clear -a0

    磁盤上下線

    # 將某塊物理盤下線/上線
    /opt/MegaRAID/MegaCli/MegaCli64 -PDOffline -PhysDrv [32:4] -a0
    /opt/MegaRAID/MegaCli/MegaCli64 -PDOnline -PhysDrv [32:4] -a0

    創建

    # 用slot2號的盤創建raid0
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r0[32:2] WB Direct -a0
    # 用slot3,4號盤創建raid1
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r1 [32:3,32:4] -a0
    # 用slot5,6,7號盤創建raid5
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [32:5,32:6,32:7] -a0
    # 用slot9,10,11,12號,創建一個raid10
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgSpanAdd -r10 -Array0[32:8,32:9] -Array1[32:10,32:11] -a0
    # 如果創建報錯 Exit Code: 0x26
    #將磁盤格式轉換一下
    /opt/MegaRAID/MegaCli/MegaCli64 -PDMakeGOOD -Physdrv [32:8] -force -aALL
    # 在第1張陣列卡上創建一個 raid5 陣列,由物理盤 1,2,3 構成,該陣列的熱備盤是物理盤 4
    # 注意這里的32:2指的是使用eID和slot ID對一個陣列卡下的硬盤進行定位(默認從0開始計數)
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [32:2,32:3,32:4] WB Direct -Hsp[32:4] -a0
    # 同上,創建一個 raid5 陣列,但是不指定熱備盤?
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [32:2,32:3,32:4] WB Direct -a0
    # 在線添加物理硬盤到某個陣列中
    /opt/MegaRAID/MegaCli/MegaCli64 -LDRecon -Start -r5 -Add -PhysDrv[32:5] -L1 -a0
    # 指定第1張陣列卡的第8塊盤作為全局熱備 (默認從0開始計數)
    /opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv[32:7] -a0?
    # 同上,指定為某個陣列的專用熱備
    /opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[32:7] -a0

    刪除

    # 刪除raid組0的raid組
    /opt/MegaRAID/MegaCli/MegaCli64 -cfglddel -L0 -a0
    # 刪除全局熱備盤?
    /opt/MegaRAID/MegaCli/MegaCli64 -PDHSP -Rmv -PhysDrv[32:7] -a0

    換盤

    # 查看磁盤健康狀態
    /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "slot number" | nl && /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "firmware state" | nl && /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "raw size" | nl
    # 查看RAID
    /opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL|egrep "Virtual Drive|RAID|^Size"
    # 查看磁盤中是哪一塊的raid占用緩存導致無法創建新的raid
    /opt/MegaRAID/MegaCli/MegaCli64 -getpreservedcachelist -a0
    # 清除占用緩存的raid (其中L4中的數字是來源于上一條命令的輸出)
    /opt/MegaRAID/MegaCli/MegaCli64 -discardpreservedcache -L2 -a0
    # 查看是否清除緩存完成
    /opt/MegaRAID/MegaCli/MegaCli64 -getpreservedcachelist -a0
    # 掃描Foreign磁盤配置
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -scan -a0
    # 清除Foreign磁盤配置
    /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -clear -a0
    # raid0更換磁盤
    # 1.查看磁盤報錯狀況,
    ll /dev/sd*
    lsblk
    # 2.查看磁盤位置
    /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "slot number" | nl && /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "firmware state" | nl && /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "raw size" | nl
    # 3.卸載磁盤錯誤目錄 (#備注:如自動掛載會自動卸載錯誤目錄,這步可忽略直接在線更換)
    umount /srv/BigData/hapdoop/data5
    # 4.現場更換磁盤
    # 查看陣列卡卡號
    /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | more
    # 創建陣列對應的磁盤位置陣列卡卡號252,slot4槽位
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r0[252:4] -a0
    /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "slot number" | nl && /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "firmware state" | nl && /opt/MegaRAID/MegaCli/MegaCli64 -PDlist -a0 | grep -i "raw size" | nl
    #(1)在確認磁盤好的情況下如不能加入陣列卡,請查看Foreign磁盤配置和磁盤cache信息,及時去清除(2)查看raid以及磁盤相關信息
    #查看是否有 preserved cache data
    /opt/MegaRAID/MegaCli/MegaCli64 -getpreservedcachelist -a0
    #有missing就清除
    /opt/MegaRAID/MegaCli/MegaCli64 -discardpreservedcache -L1 -a0
    /opt/MegaRAID/MegaCli/MegaCli64 -getpreservedcachelist -a0
    /opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r0[0:0] -a
    # 5.格式化相對應的盤 進行掛載
    mkfs.ext4 /dev/sdf
    mount /srv/BigData/hapdoop/data5
    # 備注:如果更換的新盤有數據會發現一直faild狀態,可使用強制同步,改標識good然后重新加入raid
    # 1.標識改為good
    /opt/MegaRAID/MegaCli/MegaCli64 -PDMakeGood -PhysDrv[252:6] -a0
    # 2.查看該磁盤 array和row位置
    /opt/MegaRAID/MegaCli/MegaCli64 -PdGetMissing -a0
    # 3加入陣列組
    /opt/MegaRAID/MegaCli/MegaCli64 -PdReplaceMissing -Physdrv[252:6] -array3 -row0 -a0
    # 4開始同步該磁盤
    /opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -start -physDrv[252:6] -a0
    # 5.查看該磁盤同步進度
    /opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -showprog -physDrv[252:6] -a0

    sas3ircu

    > 適用陣列卡型號

    > LSISAS3008

    > LSISAS3004

    # 查看所有RAID控制器信息
    ./sas3ircu list
    # 查看第一塊RAID控制器、volume、物理磁盤等信息。這里數字0代表第一塊RAID卡,依次類推。如果只有一塊RAID卡,也是0。
    ./sas3ircu 0 display
    # 查看第一塊RAID控制器所有邏輯磁盤信息
    ./sas3ircu 0 status
    # 刪除第一塊RAID控制器上所有RAID配置
    ./sas3ircu 0 delete noprompt
    # 在第一塊RAID控制器上將第一塊與第二塊物理磁盤配置為RAID1,分配最大使用空間。
    ./sas3ircu 0 create raid 1 max 2:0 2:1 noprompt
    # 在第一塊RAID控制器上將第三塊到第十二塊物理磁盤配置為RAID10,分配最大使用空間。(注意:LSI SAS3008最多支持2個RAID,單個RAID中最多支持10個硬盤。所有的RAID包含的硬盤總量最多14個,剩余硬盤只能以獨立的“Physical drive”方式被LSI SAS3008管理。)
    ./sas3ircu 0 create raid10 max 2:2 2:3 2:4 2:5 2:6 2:7 2:8 2:9 2:10 2:11 noprompt
    # 設置Volume ID號為286的RAID組為預先可引導模式
    ./sas3ircu 0 bootir 286
    # 配置第11塊物理硬盤為熱備
    ./sas3ircu 0 hotspare 2:10
    # 刪除熱備硬盤
    ./sas3ircu 0 hotspare delete 2:10
    # 上傳或清除日志信息
    ./sas3ircu 0 logir
    # raid0更換磁盤
    # 1.查看磁盤報錯狀況,
    ll /dev/sd*
    lsblk
    ./sas3ircu 0 display
    # 2.卸載磁盤錯誤目錄
    umount /srv/BigData/hapdoop/data5
    3.確認磁盤,這個不用加入陣列,在線換盤可直接識別
    多陣列目前不涉及計費機器,其他可在線更換

    storcli64

    參數

    /c 控制器號 輸出結果中的Controller 值
    /v RAID號
    /e 背板號 輸出結果EID值
    /f 外部配置
    /s 槽位號 輸出結果的Slt值

    查看

    # 獲取控制器號:
    storcli64 /call show all
    # 查看RAID控制器摘要信息
    storcli64 show
    # 查看詳細RAID控制器信息
    storcli64 show all
    # 查看第一塊RAID卡版本、功能、狀態、以及raid卡下的物理磁、邏輯盤信息。c0代表第一塊raid卡,如果有多塊則命令以此類推。
    storcli64 /c0 show all
    # 查看第一塊RAID卡剩下的磁盤空間
    storcli64 /c0 show freespace
    # 查看第一塊RAID卡rebuildrate速度
    storcli64 /c0 show rebuildrate
    # 查看第一塊RAID卡上物理磁盤詳細信息
    storcli64 /c0 /eall /sall show all
    # 查看磁盤重建進度
    storcli64 /c0 /e252 /sall show rebuild
    # 查看報警器信息
    storcli64 /c0 show alarm
    # 顯示第一塊RAID卡上所有邏輯磁盤相關信息,也可指定某個邏輯磁盤v0,v1等等。
    storcli64 /c0 /vall show all
    # 顯示第一塊RAID卡上第一個邏輯磁盤信息
    storcli64 /c0 /v0 show
    # 顯示bbu信息
    storcli64 /c0 /bbu show all
    # 在線查看日志
    storcli64 /c0 show termlog type=contents
    # 將日志存儲為文件
    storcli64 /c0 show events file=/home/eventreports

    刪 除

    # 強制刪除某個邏輯磁盤
    storcli64 /c0 /v0 del force
    # 清除第一塊RAID卡緩存
    storcli64 /c0 flushcache
    # 刪除熱備磁盤
    storcli64 /c0 /ex /sx delete hostsparedrive

    升級

    # 升級第一塊RAID卡固件
    storcli64 /c0 download file=mr3108fw.rom
    # 升級固件后重啟RAID卡以便新固件及時生效
    storcli64 /c0 restart

    定位

    # 定位第一塊RAID上某塊物理磁盤,物理磁盤的綠色的定位燈會閃爍。 e代表Enclosure,s代表Slot或PD
    storcli64 /c0 /e252 /s0 start locate
    # 停止定位,定位燈停止閃爍。
    storcli64 /c0 /ex /sx stop locate

    手動重建

    然陣列卡是服務器級別的東西,但不代表個人電腦就不能用,尤其是有多塊機械硬件的朋友,通過引進陣列卡一方面能夠提升讀寫速度,另一方面可以在部分硬盤壞的時候保障數據不丟失。

    最近有一塊4 T硬盤快壞了,經常找不到盤,打開這個盤的分區非常卡,整個系統都半天響應不過來。關鍵還要想辦法趁著硬盤還偶爾能打開的情況下把數據全部拷出來,非常麻煩。如果有陣列卡就不會有這么多問題了。

    如果使用帶緩存的陣列卡,在平時小文件操作的時候速度更能飛起,機械盤的容量固態盤的體驗,以下是一些臺式機適用的帶緩存的陣列卡:

    1、LSI MegaRAID:LSI(現已被 Broadcom 收購)的 MegaRAID 系列是業界知名的高性能 RAID 卡。這些卡提供了多種 RAID 級別的支持,具有內置緩存,并支持可選的電池備份單元。

    如 MegaRAID SAS 9361-8i,MegaRAID SAS 9380-8e,MegaRAID SAS 9341-4i等

    9364-8i

    有些型號支持使用固態硬盤做緩存盤,能處理大文件時提升更快的操作速度與體驗。


    2、Adaptec RAID 卡:Adaptec 提供了一系列帶緩存的 RAID 卡,支持各種 RAID 級別。這些卡具有內置緩存,支持可選的電池備份單元,并且兼容多種操作系統。

    Adaptec RAID 8805


    3、HighPoint RocketRAID:HighPoint 的 RocketRAID 系列 RAID 卡提供了多種 RAID 級別的支持,具有內置緩存,支持可選的電池備份單元,并且兼容多種操作系統。

    這款見得少,某寶上都沒看到幾個。


    4、Dell PERC:Dell PowerEdge RAID Controller(PERC)系列適用于臺式機和服務器,支持多種 RAID 級別,并提供內置緩存。這些卡通常預裝在 Dell 服務器和工作站上,但也可以單獨購買。

    DELL的陣列卡很多運維都熟悉,能用在普通臺式機上還是少見。

    h730p


    5、Hewlett Packard Enterprise (HPE) Smart Array:HPE 的 Smart Array RAID 控制器適用于臺式機和服務器,支持多種 RAID 級別,并具有內置緩存。這些卡通常預裝在 HPE 服務器和工作站上,但也可以單獨購買。


    請注意,在選擇 RAID 卡時,您需要考慮卡的性能、兼容性、接口類型(如 PCIe 插槽)、磁盤接口(如 SATA、SAS 等)、RAID 級別支持等因素。此外,還需要確保您的臺式機具有足夠的空間和電源支持,以便安裝和運行 RAID 卡。

    同時注意,這些陣列卡有些接口不一定直接是SATA,而是需要轉接線一轉4這樣的,如HD Mini-SAS SFF8643 x 2(可直接連接8個SAS/SATA裝置)。

    括ROG HYPER M.2在內,大家平時所見到的消費級PCIe SSD擴展卡大多采用單槽設計。HighPoint為1U/2U服務器設計的8盤位RAID卡SSD7749E則采用了雙槽設計,支持免工具安裝8塊9.5mm厚度的E1.S SSD。

    雙槽設計使得SSD7749E可以輕松容納E1.S規格SSD的33.75毫米寬度,并排兩個風扇將氣流直接吹向機箱外,類似于顯卡的渦輪散熱。不要小看SSD對散熱的需求,每個E1.S規格的SSD功耗最高都可達到20瓦。

    作為具備RAID功能的SSD擴展卡,HighPoint SSD7749E支持RAID0/1/10或非RAID設置。

    HighPoint SSD7749E通過PCIe 4.0 x16接口連接到服務器/個人電腦,理論帶寬28GB/s。在輕負載使用時,擴展卡還可將多達4個PCIe 4.0通道動態分配給特定的單個SSD,從而提高性能。作為服務器配件,SSD7749E定價并不便宜:1499美元,約合人民幣10888元。

網站首頁   |    關于我們   |    公司新聞   |    產品方案   |    用戶案例   |    售后服務   |    合作伙伴   |    人才招聘   |   

友情鏈接: 餐飲加盟

地址:北京市海淀區    電話:010-     郵箱:@126.com

備案號:冀ICP備2024067069號-3 北京科技有限公司版權所有